EnergyGuard by VampaTech
Devices Prerequisites Installation Alarm Setup Testing FAQ
User and Maintenance Manual - Version 1.0

Power Consumption Monitoring System

The EnergyGuard system allows you to monitor home electricity consumption (MASTER) and signal power excesses via light and sound devices (SLAVE) controlled through an App.

Download Full Manual (PDF)

WARNING - RISK OF ELECTROCUTION

Operations on the electrical panel must be performed only by qualified personnel. Incorrect installation may cause risk of electrocution or damage to the system and/or installation site. Active or passive liability is disclaimed.

Devices Summary Table

Device Function
MASTER Measures instant absorbed power
SLAVE Light signaling and acoustic alarm

System Architecture

ELECTRICAL PANEL ── Clamp ──► MASTER ── WiFi ──► APP ──► SLAVE (Bulbs + Acoustic alarm)

Installation Prerequisites

  1. Access to a 2.4 GHz Wi-Fi network with Internet connection.

    If missing: simply use a mobile router with a SIM card.

  2. Smartphone (Android or iOS) with the SmartLife (or Tuya) app installed (available for free on official stores).

    If missing: a smartphone must be purchased (even without a SIM).

  3. 230V power socket and accessible PHASE cable near the power source (e.g., the main electrical panel of the home).

    If missing: an electrical outlet must be installed (hazardous activity assigned to a qualified electrician) or the MASTER device power supply must be wired directly to the output of a miniature circuit breaker in the electrical panel (hazardous activity assigned to a qualified electrician).

Device Installation

1 Install App on Smartphone

Download the SmartLife (or Tuya) application from your smartphone store and register an account. Select the free app option. The paid version enables features that are not required for the proper functioning of the devices to be installed.
For App configuration, please refer to the manufacturer's manual available on their official website.

2 MASTER Device Installation

The MASTER device is equipped with a power plug and a current clamp sensor and lacks any light bulb. Its purpose is to detect instant power draw and transmit consumption data to the cloud App.

  • The current clamp must be installed by passing the PHASE cable (Brown, Black, or Grey) whose current (and power) flow you wish to monitor through the magnetic clamp. To do this, open the clamp and close it tightly around the PHASE wire.
  • Once installed, plug the device into a socket to power it up.
  • Follow the App manual instructions to pair the device. To do this, press the reset button on the device (located under the transparent rubber cover) for 5 seconds, then search for devices to pair via the App.
  • Once the device is detected, follow the instructions provided by the App.
  • Upon completion, a new device named Wifi Meter (or similar) should appear in the App, allowing you to read the instant power absorbed and measured by the device.
Important note: If the measured power reads negative, simply reinstall the current clamp around the PHASE wire rotated by 180°.

3 SLAVE Devices Installation

To install the SLAVE devices (those with light bulbs), plug the device into a power socket, press the reset button for at least 5 seconds (if present) or rotate the device 180° and plug it back in, then proceed with pairing via the App.

  • Follow the App instructions for pairing.
  • Once paired, a new device called Smart Switch (or similar) will be visible in the App, allowing you to turn the light bulb on or off directly from the App.
  • The acoustic alarm can be disabled by switching the side toggle to “OFF”.

Power Consumption Alarm Configuration

D1) “Power Excess” Scenario

  1. In the App, go to the “Smart” section (bottom menu) and select “Automation” (top menu).
  2. Create a new scenario (tap the “+” button top right), select “When device status changes”, select “single device” and choose the MASTER device, then select “Total Power” and “Greater than”. This is the condition section identified as “IF”.
  3. Here you set the threshold above which the MASTER device will trigger the alarm on the SLAVE devices. Typically, for a standard 3kW household contract, the limit is set to 3.3kW to prevent automatic power trips if consumption exceeds the max limit (3kW) + 10% (0.3kW) for a few minutes.
  4. As an effect when consumed power exceeds the threshold (section identified as “THEN”), select each individual SLAVE device one by one and set “switch1” to “ON”.
  5. This ensures that IF the consumed power exceeds the set limit, THEN the system turns on the SLAVE devices.
  6. You can also send a notification message to your phone by selecting “messages” in the “THEN” section.

D2) “Normal Power” Scenario

  1. In the App, go to the “Smart” section (bottom menu) and select “Automation” (top menu).
  2. Create a new scenario (tap the “+” button top right), select “When device status changes”, select “single device” and choose the MASTER device, then select “Total Power” and “Less than”. This is the condition section identified as “IF”.
  3. Here you set the threshold below which the MASTER device will deactivate the alarm on the SLAVE devices. Typically, for a 3kW household contract, this is set to 3.0kW.
  4. As an effect when consumed power drops below the threshold (section identified as “THEN”), select each individual SLAVE device one by one and set “switch1” to “OFF”.
  5. This ensures that IF the consumed power drops below the set limit, THEN the system turns off the SLAVE devices.

SYSTEM TESTING

Turn on multiple high-power appliances simultaneously (e.g., electric oven, hair dryer, electric heater, induction cooktop, etc.) and check that the SLAVE devices turn on.
When turning appliances off and power consumption drops below the level configured in section D2, the alarms will automatically turn off after a few seconds.

FREQUENTLY ASKED QUESTIONS

Solution: verify the availability of the 2.4 GHz Wi-Fi network where the device is placed.

Solution: during setup, if the device is not detected, try moving it closer to the Wi-Fi modem.

Solution: no action is required; once power is restored, previously configured devices will automatically reconnect to the app within a few minutes.

Solution: flip the magnetic current sensor (toroid) installed on the PHASE wire by 180°.

Solution: once the password/router is changed, all devices must be reconfigured following previous instructions.

Solution: the maximum number of installable devices depends on Wi-Fi characteristics and App specs, but it is not a system constraint. For maximum system effectiveness, simply install a SLAVE device in all rooms where power overload warnings are needed, such as areas with high-consumption appliances like:

  • kitchen (electric oven, dishwasher, electrical tools)
  • bathroom (hair dryer, electric heaters)
  • laundry room (washing machine, dryer, iron)
  • garage / cellar (heavy tools, appliances)

Solution: the power cable can be adjusted to system needs. WARNING: modifications must be performed by qualified personnel.

Solution: shortening the current sensor cable requires opening the MASTER housing. It is recommended to have modifications done by qualified personnel only after disconnecting the device from the mains power supply.

Technical Support

For assistance or information regarding the EnergyGuard system:

e-mail: support@vampatech.com